Gas Purifiers and Traps
- (1)
- (2)
- (2)
- (2)
- (2)
- (2)
- (1)
- (5)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (2)
- (2)
- (2)
- (2)
- (2)
- (11)
- (2)
- (1)
- (2)
- (1)
- (6)
- (2)
- (2)
- (1)
- (1)
- (2)
- (6)
- (4)
- (3)
- (1)
- (2)
- (1)
- (3)
- (2)
- (3)
- (3)
- (5)
- (5)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
Filtered Search Results
Shimadzu Scientific Instruments STAINLESS STEEL CROSS AND FITT
NC3525528 STAINLESS STEEL CROSS AND FITT
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cole-Parmer Chromatography Research Supplies Carbon Dioxide Traps; 40 liters volume; 1/4" fittings
Traps remove carbon dioxide from your gas stream. A 500-mL nickel-plated carbon steel cylinder holds packed absorbent (80% emulsive, 320 g; 20% NaOH, 70 g); withstands up to 1000 psi. Include drying stage to prevent moisture from entering system. If downstream moisture is harmful to application, a second drying stage is recommended. Trap measures 15"L x 2" dia; frits are integral to each fitting. Regeneration or refilling is not recommended. Shpg wt 3 lb (1.4 kg).
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Trajan Scientific and Medical Gas Filter - Carrier Gas
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
Trajan Scientific and Medical Gas Filter Kit - Carrier Gas
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
| Includes | 1 x 1-position connecting unit, 1 x gas filter (carrier gas) |
|---|---|
| Type | Carrier Gas |
| Capacity (Metric) | 100 mL |
MilliporeSigma™ Supelco™ Supelpure™-O Oxygen/Moisture Trap, S-Trap
Can reduce oxygen to less than 2 ppb when the level in the incoming gas does not exceed 10 ppm
Trajan Scientific and Medical Gas Filter Kit - FID
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
| Includes | 1 x 4-position connecting unit, 4 x gas filters (2 x hydrocarbon, 1 x oxygen, 1 x moisture) |
|---|---|
| Type | Carrier Gas |
| Capacity (Metric) | 150 mL |
Trajan Scientific and Medical Gas Filter Connecting Unit, High Flow
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
The gas filter connecting unit has inlet and outlet connectors for the gas line and the system can be wall-mounted or fixed to a bench. Connecting units come with a 1, 2 or 4 filter capacity and are available for 1/4 in. or 1/8 in. gas lines
| Type | 2-position Connecting Unit High Flow |
|---|---|
| For Use With (Equipment) | Gas filters |
| Packaging Quantity | Each |
Trajan Scientific and Medical Gas Filter - Moisture
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
Trajan Scientific and Medical Gas Filter Connecting Unit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
The gas filter connecting unit has inlet and outlet connectors for the gas line and the system can be wall-mounted or fixed to a bench. Connecting units come with a 1, 2 or 4 filter capacity and are available for 1/4 in. or 1/8 in. gas lines
| For Use With (Equipment) | Gas filters |
|---|---|
| Packaging Quantity | Each |
Trajan Scientific and Medical Gas Filter - Hydrocarbon
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.
Trajan Scientific and Medical Gas Filter - Oxygen
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Prevent contaminants in gases from significantly impacting the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column, excessive bleed and septa degradation.